beautypg.com

Displaying the link trace cache, Displaying the link, Trace cache – LevelOne GTL-2691 User Manual

Page 507

background image

C

HAPTER

14

| Basic Administration Protocols

Connectivity Fault Management

– 507 –

D

ISPLAYING

THE

L

INK

T

RACE

C

ACHE

Use the Administration > CFM > Show Information (Show Link Trace

Cache) page to show information about link trace operations launched from

this device.

CLI R

EFERENCES

"show ethernet cfm linktrace-cache" on page 1342

"clear ethernet cfm linktrace-cache" on page 1342

P

ARAMETERS

These parameters are displayed:

Hops – The number hops taken to reach the target MEP.

MA – Maintenance association name.

IP/Alias – IP address or DNS alias of the target device’s CPU.

Forwarded – Shows whether or not this link trace message was

forwarded. A message is not forwarded if received by the target MEP.

Ingress MAC Address – MAC address of the ingress port on the target

device.

Egress MAC Address – MAC address of the egress port on the target

device.

Ingress Action – Action taken on the ingress port:

IngOk – The target data frame passed through to the MAC Relay

Entity.

IngDown – The bridge port’s MAC_Operational parameter is false.

This value could be returned, for example, by an operationally

Down MEP that has another Down MEP at a higher MD level on the

same bridge port that is causing the bridge port’s MAC_Operational

parameter to be false.

IngBlocked – The ingress port can be identified, but the target data

frame was not forwarded when received on this port due to active

topology management, i.e., the bridge port is not in the forwarding

state.

IngVid – The ingress port is not in the member set of the LTM’s

VIDs, and ingress filtering is enabled, so the target data frame was

filtered by ingress filtering.

Egress Action – Action taken on the egress port:

EgrOk – The targeted data frame was forwarded.

EgrDown – The Egress Port can be identified, but that bridge port’s

MAC_Operational parameter is false.

EgrBlocked – The egress port can be identified, but the data frame

was not passed through the egress port due to active topology

management, i.e., the bridge port is not in the forwarding state.