Sending simple mail transfer protocol alerts – LevelOne GTL-2691 User Manual

Page 409

background image

C

HAPTER

14

| Basic Administration Protocols

Configuring Event Logging

– 409 –

Figure 215: Configuring Settings for Remote Logging of Error Messages

S

ENDING

S

IMPLE

M

AIL

T

RANSFER

P

ROTOCOL

A

LERTS

Use the Administration > Log > SMTP page to alert system administrators

of problems by sending SMTP (Simple Mail Transfer Protocol) email

messages when triggered by logging events of a specified level. The

messages are sent to specified SMTP servers on the network and can be

retrieved using POP or IMAP clients.

CLI R

EFERENCES

"SMTP Alerts" on page 805

P

ARAMETERS

These parameters are displayed:

SMTP Status – Enables/disables the SMTP function. (Default: Enabled)

Severity – Sets the syslog severity threshold level (see table on

page 406

) used to trigger alert messages. All events at this level or

higher will be sent to the configured email recipients. For example,

using Level 7 will report all events from level 7 to level 0.

(Default: Level 7)

Email Source Address – Sets the email address used for the “From”

field in alert messages. You may use a symbolic email address that

identifies the switch, or the address of an administrator responsible for

the switch.

Email Destination Address – Specifies the email recipients of alert

messages. You can specify up to five recipients.

Server IP Address – Specifies a list of up to three recipient SMTP

servers. The switch attempts to connect to the other listed servers if

the first fails.