beautypg.com

Underflow-limit – Brocade Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide (Supporting R05.6.00) User Manual

Page 82

background image

58

Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide

53-1003031-02

underflow-limit

1

underflow-limit

This command sets the underflow-limit to the input value.

The [no] function of the command sets the underflow-limit back to the default value.

Syntax

[no] underflow-limit value

Parameters

underflow-limit

The number of consecutive samples which have to be below the threshold to trigger a
premature adjustment.

value

Default is 0, meaning there is no premature adjustment because of underflow.

Command

modes

This command operates in MPLS sub-configuration mode (config-mpls-autobw-template-template1,
config-mpls-lsp-lsp1).

History

Release

Command history

Multi-Service NetIron Release 05.6.00 The command was introduced.

Related