Brocade Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide (Supporting R05.6.00) User Manual
Page 75
![background image](/manuals/361646/75/background.png)
Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide
51
53-1003031-02
show mpls lsp detail/extensive
1
Example
Brocade# show mpls lsp extensive
LSP lsp1, to 10.23.23.23
From: 10.34.34.34, admin: UP, status: UP, tunnel interface(primary path):
tnl1
minimum bw
The configured minimum bandwidth.
maximum bw
The configured maximum bandwidth.
overflow limit
Displays the configured overflow-limit value.
underflow limit
The number of sample which have to be below the threshold to trigger a premature
adjustment.
sample-record
Whether the template is set to record the sample history.
Constraint-based
routing enabled
Whether CSPF is in effect for the LSP.
hop limit
The maximum number of hops a path calculated by CSPF can have, set with the
hop-limit command.
Soft preemption enabled:
Soft preemption minimizes traffic disruptions and gracefully reroute the preempted
LSPs.
Active path attributes:
Tunnel interface:
The MPLS tunnel interface port ID.
outbound interface
The outbound interface taken by the active path of the LSP. when the egress
interface is a VE-enabled interface, the VE interface ID specified by the vid variable is
displayed here in the ‘Outbound interface’ field.
Tunnel index
The tunnel index for the active path of the LSP.
Tunnel instance:
outbound label
The outbound label used by the active path of the LSP.
Auto-bandwidth running info mode
adjustment interval:
Displays the configured adjustment-timer value.
adjustment threshold:
Displays the configured adjustment-threshold value.
overflow limit:
Displays the configured overflow-limit value.
underflow limit:
The number of sample which have to be below the threshold to trigger a premature
adjustment.
minimum bw
The configured minimum bandwidth.
maximum bw:
The configured maximum bandwidth.
Samples collected:
Number of samples collected so far in the current adjustment-interval.
max sampled bw:
The maximum of the samples collected so far in the current adjustment-interval.
last sample:
The last sampled-bandwidth.
Sample-record:
Whether the template is set to record the sample history.
adjustment due in:
Displays the time remaining for the current adjust-interval to expire.
Adjustment ignored:
This consecutive number of times the adjustment was ignored due to any reason.
Current bandwidth:
Current running bandwidth.
Recorded routes:
The addresses recorded by the RECORD_ROUTE object during RSVP signaling.
Field output
Description