show mpls lsp detail/extensive

1

Example

Brocade# show mpls lsp extensive

LSP lsp1, to 10.23.23.23

From: 10.34.34.34, admin: UP, status: UP, tunnel interface(primary path):

tnl1

minimum bw

The configured minimum bandwidth.

maximum bw

The configured maximum bandwidth.

overflow limit

Displays the configured overflow-limit value.

underflow limit

The number of sample which have to be below the threshold to trigger a premature
adjustment.

sample-record

Whether the template is set to record the sample history.

Constraint-based
routing enabled

Whether CSPF is in effect for the LSP.

hop limit

The maximum number of hops a path calculated by CSPF can have, set with the
hop-limit command.

Soft preemption enabled:

Soft preemption minimizes traffic disruptions and gracefully reroute the preempted
LSPs.

Active path attributes:

Tunnel interface:

The MPLS tunnel interface port ID.

outbound interface

The outbound interface taken by the active path of the LSP. when the egress
interface is a VE-enabled interface, the VE interface ID specified by the vid variable is
displayed here in the ‘Outbound interface’ field.

Tunnel index

The tunnel index for the active path of the LSP.

Tunnel instance:

outbound label

The outbound label used by the active path of the LSP.

Auto-bandwidth running info mode

adjustment interval:

Displays the configured adjustment-timer value.

adjustment threshold:

Displays the configured adjustment-threshold value.

overflow limit:

Displays the configured overflow-limit value.

underflow limit:

The number of sample which have to be below the threshold to trigger a premature
adjustment.

minimum bw

The configured minimum bandwidth.

maximum bw:

The configured maximum bandwidth.

Samples collected:

Number of samples collected so far in the current adjustment-interval.

max sampled bw:

The maximum of the samples collected so far in the current adjustment-interval.

last sample:

The last sampled-bandwidth.

Sample-record:

Whether the template is set to record the sample history.

adjustment due in:

Displays the time remaining for the current adjust-interval to expire.

Adjustment ignored:

This consecutive number of times the adjustment was ignored due to any reason.

Current bandwidth:

Current running bandwidth.

Recorded routes:

The addresses recorded by the RECORD_ROUTE object during RSVP signaling.

Field output

Description