beautypg.com

Display considerations for vpls information, Displaying vpls summary information – Brocade Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide (Supporting R05.6.00) User Manual

Page 521

background image

Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide

497

53-1003031-02

Displaying VPLS information

3

Information about individual VPLS instances configured on the device

Detailed information about VPLS instances

Information about a specified VPLS ID or VPLS name

Information about VPLS instances that are not fully operational

The contents of the VPLS MAC database for a VPLS instance

The VPLS MAC database entries on the Management Processor (MP)

VPLS traffic statistics

VPLS CPU protection configuration status

Display considerations for VPLS information

The VPLS information that is displayed in the output of the show mpls vpls commands has
changed. Previously, when a VPLS was created, a range of VC labels was allocated to the VPLS
instance. Now, there is no pre-allocation of VC label ranges to a VPLS instance.

The range of the allocated VC labels is no longer displayed in the output of the following show mpls
vpls commands. Refer to the subsequent sections for more information on changes to the show
mpls vpls command outputs:

show mpls vpls brief -

“Displaying information about VPLS instances”

on page

498

show mpls vpls detail -

“Displaying detailed information about VPLS instances”

on page

498

show mpls vpls down -

“Displaying information about VPLS instances that are not operational”

on page

505

show mpls vpls id -

“Displaying information about a specified VPLS ID or VPLS name”

show mpls vpls summary -

“Displaying VPLS summary information”

Displaying VPLS summary information

The show mpls vpls summary command has changed. The VC label allocation range size field is no
longer displayed in the output of the show mpls vpls summary command.

The user can display a summary of VPLS information, including the number of VPLS instances,
number of VPLS peers, maximum size of the VPLS MAC database, VPLS raw mode, and the values
of the VPLS global MTU, and the value of the remote VC MTU.

Brocade# show mpls vpls summary

Virtual Private LAN Service summary:

Total VPLS configured: 3, maximum number of VPLS allowed: 4096

Total VPLS peers configured: 1, total peers operational: 1

Maximum VPLS macentries allowed: 8192, currently installed: 3

VPLS global raw mode VC-Type is Ethernet (0x5)

VPLS global MTU is 1500, MTU enforcement is OFF

Global CPU protection: OFF

MVIDs in use: 1 of 1 total allocated

Syntax: show mpls vpls summary