Display considerations for vpls information, Displaying vpls summary information – Brocade Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide (Supporting R05.6.00) User Manual
Page 521
Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide
497
53-1003031-02
Displaying VPLS information
3
•
Information about individual VPLS instances configured on the device
•
Detailed information about VPLS instances
•
Information about a specified VPLS ID or VPLS name
•
Information about VPLS instances that are not fully operational
•
The contents of the VPLS MAC database for a VPLS instance
•
The VPLS MAC database entries on the Management Processor (MP)
•
VPLS traffic statistics
•
VPLS CPU protection configuration status
Display considerations for VPLS information
The VPLS information that is displayed in the output of the show mpls vpls commands has
changed. Previously, when a VPLS was created, a range of VC labels was allocated to the VPLS
instance. Now, there is no pre-allocation of VC label ranges to a VPLS instance.
The range of the allocated VC labels is no longer displayed in the output of the following show mpls
vpls commands. Refer to the subsequent sections for more information on changes to the show
mpls vpls command outputs:
•
“Displaying information about VPLS instances”
•
show mpls vpls detail -
“Displaying detailed information about VPLS instances”
•
“Displaying information about VPLS instances that are not operational”
•
show mpls vpls id -
“Displaying information about a specified VPLS ID or VPLS name”
•
show mpls vpls summary -
“Displaying VPLS summary information”
Displaying VPLS summary information
The show mpls vpls summary command has changed. The VC label allocation range size field is no
longer displayed in the output of the show mpls vpls summary command.
The user can display a summary of VPLS information, including the number of VPLS instances,
number of VPLS peers, maximum size of the VPLS MAC database, VPLS raw mode, and the values
of the VPLS global MTU, and the value of the remote VC MTU.
Brocade# show mpls vpls summary
Virtual Private LAN Service summary:
Total VPLS configured: 3, maximum number of VPLS allowed: 4096
Total VPLS peers configured: 1, total peers operational: 1
Maximum VPLS macentries allowed: 8192, currently installed: 3
VPLS global raw mode VC-Type is Ethernet (0x5)
VPLS global MTU is 1500, MTU enforcement is OFF
Global CPU protection: OFF
MVIDs in use: 1 of 1 total allocated
Syntax: show mpls vpls summary