Displaying LDP information

2

The following example displays a VC type mismatch where two VC FEC_CBs are displayed for the
same VC ID of 1000. In the example, the user can see that one VC type displays 5, and the other VC
type displays 11. The two VC FEC_CBs are not associated with each other in any way. The VC type
mismatch causes the VC label to display a Retained state instead of an Installed state.

Brocade# show mpls ldp fec vc 1000

FEC_CB: 0x29391234, idx: 5, type: 128, pend_notif: None

State: retained, Ingr: Yes, Egr: Yes, UM Dist. done: No

VC-Id: 1000, vc-type: 5, grp-id: 0, local-mtu: N/A, remote-mtu: 1500

Downstream mappings:

Local LDP ID Peer LDP ID Label State CB

10.128.128.28:0 10.125.125.1:0 983040 Retained 0x29391140(-1)

FEC_CB: 0x29391510, idx: 4, type: 128, pend_notif: None

State: current, Ingr: Yes, Egr: Yes, UM Dist. done: Yes

VC-Id: 1000, vc-type: 11, grp-id: 0

Local-mtu: 1500, remote-mtu: N/A, MTU enforcement: enabled

Upstream mappings:

Local LDP ID Peer LDP ID Label CB

10.128.128.28:0 10.125.125.1:0 983041 0x2939141c(-1)