Initializing the Software

813

The runtime display (usually set in the Configure Auto Display
block) is configured to display the actual position and status of axes 0
and 1.

The value of all user variables is set to zero.

The value of all cam table points is set to zero.

The application program is cleared.

The application menu password (usually entered in the General page
of the Configure Control Options dialog box) is reset to APP.

Status 0 LED glows a continuous, uninterrupted red, except
1394GMC Turbo.

After communication is restored or the problem is fixed, the above
parameters must be set back to their appropriate values for your
application. You can do this manually from the motion controller’s built-
in setup menus, or by downloading the application program with
Download Axis/Drive Data with the Diagram selected in the General
page of the Configure Control Options dialog box.

To clear the Status 0 LED:

1. Wait until the parameters (described above) have been reset to the

initialized values for your application.

2. Press and release the controller’s RESET button.