Publication GMLC-5.2 - November 1999

Motion Controller Functions

613

Insert a value or expression equal to the desired address. The argument is
evaluated as an integer (floating point values are truncated) and must have
a value from 0 to 11 inclusive. The Input function evaluates as 1 (true) if
the input is ON, and 0 (false) if it is OFF.

Miscellaneous Inputs

Use the Miscellaneous Input function to include the state of the non-axis-
specific, dedicated input on the motion controller in an expression.

Syntax:

Miscellaneous_input[input number]

Insert a value or expression equal to the desired input number from the
table below.

The argument is evaluated as an integer (floating point values are
truncated) and must have a value from 0 to 9 inclusive.

Input
Number

Description

0

Initialization Input

1

Application Lock

2

Data Lock (Compact, Integrated, and Basic only)

3

Plug Lock

4

External Enable 1394 (1394 only)

5

Hard Fault 1394 (1394 only)

6

Watchdog OK 1394 (1394 only)

7

Dualport Initialization 1394 (1394 only)

8

DSP Bus Grant

9

DH485 Switch