beautypg.com

Defining output floats – Rockwell Automation GMLC Reference Manual User Manual

Page 827

background image

Publication GMLC-5.2 - November 1999

790

1394 GMC Turbo SLC Interface

5. Select OK. The dialog box closes, and the new input appears in the

Tag Window.

Defining Output Floats

Output floats can pass user variables and a select list of system variables.
If you have enabled output floats, you must link each floating point output
to a user variable that is the source of the floating-point value. To do this:

1. In the Tag Explorer, select Output Float.

2. In the Tag Window, single-click the right mouse button. A variable

short-cut menu appears.

3. Select New. The SLC Output Float dialog box appears.

Address

Type the address, or number, of the bit (from 0
to 39).
Note:

The available address range depends on
the number of Output Bits you specified
in the SLC page of the Configure
Control Options dialog box. See
Defining the I/O Configuration.

Field

Description