Running your program – Rockwell Automation GMLC Reference Manual User Manual
Page 156

Publication GMLC-5.2 - November 1999
Adjusting Dynamics Values for the Servo Axis
119
•
Error Tolerance – Select the up or down arrows to change how
much error (relative to the position of the axis) the controller tol-
erates before indicating a position error fault.
3. Saving Settings
•
Save to Power-up – Saves changed working values as the power-
up (or start-up) values in the controller
•
Save – Saves changed working values as the power-up values in
the Dynamics dialog box
Note:
This does not change the power-up values in the controller until
you download with axis/drive data selected, download via the
Apply page, or press the Save to Power up in the Adjust
Dynamics page.
•
Save then select OK in the Configure Axis Use dialog box – Save
changed working values as offline power-up values.
•
Cancel – Not save the changes
Note: Generally, you will not need to modify the self-tuned parameters
for axis dynamics.
Running your Program
To control your program from the Adjust Dynamics page, do the
following:
•
Start Program – Starts the application program in the controller.
•
Stop Program – Stops the application program in the controller
with the feedback remaining enabled and motion stopping at
100% of the deceleration rate.
•
Kill Control – Kills the control with the feedback disabled and
motion stopping immediately on all axes.
•
Reset All – Resets the values on this page to the controller’s start-
up values.