beautypg.com

Motion controller functions – Rockwell Automation GMLC Reference Manual User Manual

Page 641

background image

Publication GMLC-5.2 - November 1999

604

System Functions

Motion Controller Functions

Motion controller functions provide indirect addressing of variables and
direct access to cam profile tables and the discrete I/O of the motion
controller. The available motion controller functions are listed below.

Function

Argument

Indirect_variable

Address:
0 – 999 for Integrated and Basic controllers
0 – 1999 for Compact and 1394 controllers

Indirect_DH_variable

File Type

,

File Number, Element, Supplement

Indirect_SLC_M0F_variable

Address 0 – 255

Indirect_SLC_M0I_variable

Address 0 – 511

Indirect_SLC_M1F_variable

Address 0 – 255

Indirect_SLC_M1F_variable

Address 0 – 511

RIO_adapter_variable

Address, Type, Scale Factor

RIO_scanner_variable

Rack, Group, Type, Scale Factor

Task_status

Task Number 0 – 9

Input

Address 0 – 11

Miscellaneous_input

Input Number 0 – 9

Axis_input

Input Number 0 – 9

RIO_input

Address 0 – 99

RIO_scanner_input

Group, Address

SLC_bit_input

Address 0 – 39

AxisLink_input

Controller Node 0 - 15, Address 0 – 15

Flex_IO_input

Module 0 - 7, Address 0 – 15

Flex_IO_analog_input

Module 0 - 7, Address 0 – 7

Group_input

Address 0 – 11, Total Signals in Group 1 - 12, Optional
Mask