Publication GMLC-5.2 - November 1999
Motion Controller Functions
609
Indirect SLC M0 Integer Variable
Use the Indirect_SLC_M0_Integer_variable to transfer large, non-time-
critical groups of data—such as endpoints and CAM tables—from the
SLC to the 1394 GMC Turbo in integer format.
You define and select SLC M0 Integers using the Tag Explorer (under
SLC M0 Integer) and the Tag Window. It is not necessary to use the
Indirect SLC M0 Integer Variable function to specify them directly.
Syntax:
Indirect_SLC_M0_Integer_variable[variable number]
Insert a value or expression equal to the desired variable number. The
argument is evaluated as an integer, and must have a value from 0 to 511.
Indirect SLC M1 Float Variable
Use the Indirect_SLC_M1_Float_variable to transfer large, non-time-
critical groups of data—such as endpoints and CAM tables—from the
1394 GMC Turbo to the SLC floating point format.
You define and select SLC M1 Floats using the Tag Explorer (under SLC
M1 Float) and the Tag Window. It is not necessary to use the Indirect SLC
M1 Float Variable function to specify them directly.
Syntax:
Indirect_SLC_M1_Float_variable[variable number]
Insert a value or expression equal to the desired variable number. The
argument is evaluated as a floating-point value, and must have a value
from 0 to 255.
Indirect SLC M1 Integer Variable
Use the Indirect_SLC_M1_Integer_variable to transfer large, non-time-
critical groups of data—such as endpoints and CAM tables—from the
1394 GMC Turbo to the SLC in integer format.