AxisLink general faults are prioritized from highest to lowest in the order
shown in the table above. A timeout accessing another controller’s data
has higher priority than a timeout accessing another controller’s AxisLink
outputs. This means that when multiple faults are active, the
AxisLink_fault_code value represents the highest priority fault on any

35

Timeout Accessing Controller 3 Outputs

Flashing Red

34

Timeout Accessing Controller 2 Outputs

Flashing Red

33

Timeout Accessing Controller 1 Outputs

Flashing Red

32

Timeout Accessing Controller 0 Outputs

Flashing Red

31

Link Error Accessing Controller 15

Flashing Green

30

Link Error Accessing Controller 14

Flashing Green

29

Link Error Accessing Controller 13

Flashing Green

28

Link Error Accessing Controller 12

Flashing Green

27

Link Error Accessing Controller 11

Flashing Green

26

Link Error Accessing Controller 10

Flashing Green

25

Link Error Accessing Controller 9

Flashing Green

24

Link Error Accessing Controller 8

Flashing Green

23

Link Error Accessing Controller 7

Flashing Green

22

Link Error Accessing Controller 6

Flashing Green

21

Link Error Accessing Controller 5

Flashing Green

20

Link Error Accessing Controller 4

Flashing Green

19

Link Error Accessing Controller 3

Flashing Green

18

Link Error Accessing Controller 2

Flashing Green

17

Link Error Accessing Controller 1

Flashing Green

16

Link Error Accessing Controller 0

Flashing Green

0

No AxisLink General Fault

Green

Fault
Code

Description

LED Color