Publication GMLC-5.2 - November 1999

114

Configuring Axis Use

Note:

Note: For Compact, Integrated, and Basic controllers only.

5. Saving Changes

Save to Power-up – Saves changed working values as the power-
up (or start-up) values in the controller

Save – Saves changed working values as the power-up values in
the Gains dialog box

Note: This does not change the power-up values in the controller until

you download with axis/drive data selected, download via the
Apply page, or press the Save to Power up in the Adjust Gains
page.

Save then select OK in the Configure Axis Use dialog box
Saves changed working values as offline power-up values

Cancel – Not save the changes

Note: Generally, you will not need to modify the self-tuned parameters

for axis gains.

Running your Program

To control your program from the Adjust Gains page, use the following:

Start Program – Starts the application program in the controller.

Stop Program – Stops the application program in the controller
with the feedback remaining enabled and motion stopping at
100% of the deceleration rate.

Kill Control – Kill the control with the feedback disabled and
motion stopping immediately on all axes.

Reset All – Resets the values on this page to the controller’s
power-up (start-up) values.