Publication GMLC-5.2 - November 1999

590

Status Variables

SLC Status

SLC_status is an integer value identifying the mode in which the SLC is
operating, as follows:

When SLC_status = 0 (Program mode), the SLC is in the mode for
creating or programming a ladder logic program in the SLC.

When SLC_status = 1 (Run mode), the SLC is executing or running a
previously programmed SLC ladder logic program.

When SLC_status = 3 (Faulted mode), a system-level fault has occurred
in the SLC. Refer to your SLC documentation for a description of these
faults, and how to handle them.

In the Tag Explorer select General System Variables, then select
SLC_status in the Tag Window.

SLC_MO_Update_Acknowledge

SLC_M0_Update_Acknowledge is a logical (Boolean) variable with a
value of:

1 (true) if the 1394 Turbo controller affirmatively acknowledges an
SLC_M0_Update_Request from the SLC, and permits the MO file
transfer, and

0 (false) if the 1394 Turbo controller has not acknowledged the
SLC_M0_Update_Request (or if the transfer is complete).

SLC MO Update Request

SLC_M0_Update_Request is a logical (Boolean) variable with a value of:

Status

Description

0

Program Mode

1

Run Mode

2

(not used)

3

Faulted Mode