Publication GMLC-5.2 - November 1999

601

System Smart Power Motor Power Percent Used 1394

The System_smrt_pwr_mtr_pwr_%_used_1394 variable reports
motoring (forward direction) power utilization in the Smart Power system
module, as a percentage of the 34 Amperes Root Mean Square (RMS)
continuous current limit.

System Smart Power PIC Software Version 1394

The System_smrt_pwr_pic_sftwr_ver_1394 defines the software version
of the Programmable Interface Controller (PIC) processor in the Smart
Power system module.

System Smart Power Regenerative Power Percent Used 1394

The System_smrt_pwr_regn_pwr_%_used_1394 variable reports
regenerative (backward direction) power utilization in the Smart Power
system module, as a percentage of the 34 Amperes Root Mean Square
(RMS) continuous current limit.

System Smart Power Shunt Power Percent Used 1394

The System_smrt_pwr_shunt_pwr_%_used_1394 variable represents the
sum of Smart Power system module forward (motoring) and backward
(regenerative) currents, as a percentage (from 0 to 100%) of the 34
Amperes Root Mean Square (RMS) continuous current limit.