beautypg.com

Rockwell Automation GMLC Reference Manual User Manual

Page 788

background image

Publication GMLC-5.2 - November 1999

Using Block Transfers

751

For example, a returned status code value of 028C hex for an axis
indicates that a registration event for the axis has occurred and that the
axis is moving, electronic gearing is enabled, and feedback is

ON

(028C

hex = 0000 0010 1000 1100 binary). See the Status Variables chapter of
this manual for more information on these conditions.

RIO Adapter Block Transfer Read
Status Code Returned Value Bits

Bit

Is Identical to Variable . . .

Runtime
Display

Hex.

Oct

10

20

AxisLink_status

F
E
D
C

17
16
15
14

PCAM_auto_correction_status
PCAM_pending_profile_status
PCAM_profile_status
Output_limit_status

OUT LIM

B
A
9
8

13
12
11
10

Watch_Pos_status
TCAM_status
Registration_status
PCAM_status

MOVING

7
6
5
4

7
6
5
4

Move_status
Lock_status
Jog_status
Homing_status

MOVING
LOCKED
JOGGING
HOMING

3
2
1
0

3
2
1
0

Gearing_status
Feedback_status
Decel_status
Accel_status

SRV OFF