beautypg.com

Rockwell Automation GMLC Reference Manual User Manual

Page 609

background image

Publication GMLC-5.2 - November 1999

572

Status Variables

Axis status conditions are prioritized from highest to lowest in the order
shown in the table. The higher the status value, the higher its priority (or
severity). This means that when a given status is active, other status
conditions of lower priority may also be active. For instance, if a
hardware overtravel fault is active for an axis, a servo output limited or
feedback OFF condition may also be active on the axis. When the highest
priority status is no longer active, Axis_status takes the value of the next
highest priority condition.

Seven of the Axis_status variable values (7 - 11, 13, 14) are fault
conditions. They are identical to the top seven Axis_fault variable values
as shown in the table below.

4

Homing

HOMING

3

Moving or
Executing Time-Lock Cam

MOVING

2

Jogging

JOGGING

1

Axis Unlocked

UNLOCK

0

Axis Locked

LOCKED

Axis
Status

Axis
Fault

Description

Runtime
Display

14

7

AxisLink timeout

AXL FLT

13

6

AxisLinkFailed (axis not found)

AXL FLT

11

5

Drive Fault

DRV OFF

10

4

Position Error Tolerance Fault

ERR FLT

9

3

Hardware Overtravel Fault

HRD FLT

8

2

Software Travel Limits Fault

SFT LIM

7

1

Encoder Noise or Loss Fault

ERR FLT

Status
Code

Description

Runtime
Display

Se

rv

o

M

a

st

e

r On

ly

V

irtu

a

l

Imag

in

ar

y