beautypg.com

Rockwell Automation GMLC Reference Manual User Manual

Page 618

background image

Publication GMLC-5.2 - November1999

581

Position Lock Cam Pending Profile Status

PCAM_pending_profile_status is a logical (Boolean) variable which has
values of:

1 (true) if a new position-lock cam profile is currently pending for the
axis

0 (false) if not

In the Tag Explorer, select both Axis System Variables and the desired
physical or imaginary axis, then select PCAM_pending_profile_status in
the Tag Window.

Pending position-lock cams are set up by choosing Pending Position-
Lock from the Cam Type pop-up menu in the Configure Cam block.

Position Lock Cam Auto-Correction Status

PCAM_auto_correction_status is a logical (Boolean) variable which has
values of:

1 (true) if auto-correction is currently enabled on the specified axis

0 (false) if not

.

Master Position

Current

Profile

New

Profile

Slave Position

PCAM_pending_
profile_status

Pending (New)
Position-Lock Cam
Configured