Description
The Rockwell Automation 45LFM–CMBA1–D5 Label Sensor
is an innovative electronic sensor used to sense and/or count
labels. A signal is generated as the edge of the label passes
through the sensor. It can be configured to sense the leading
or trailing edge.
Features
S
Consistently senses the presence of most labels on a web
S
Clear labels on clear backing
S
Clear labels on opaque backing
S
Opaque labels on clear backing
S
Opaque labels on opaque backing
S
Count 50,000 labels per minute with registration error less
than 0.01 inch
S
Heavy-duty metal housing
S
Ideal for label counting and label registering applications
Specifications
Supply Voltage &
Current
11 to 30V DC @ 50 mA max
Power-Up or Reset
Delay
10microseconds
Leakage Current 5µA
Output Configuration Complimentary: NPN and PNP
Output Rating 150mA max
Short Circuit Protection Yes
Reverse Polarity
Protection
Yes
Output Invert Control Yes
Registration Accuracy 0.025mm (0.01in)
Response Time 10microseconds
Maximum Switching
Speed
10KHz
Minimum Gap or
Label Size
0.76mm (0.03in)
Indicators Edge, zero
Construction Anodized aluminum
Environmental Rating IP54
Connections
5Ćpin micro QD
Operating Conditions 4_C to 50_C (40_F to 120_F)
Approvals CE marked for all applicable directives
Mounting the Sensor
Mount the sensor perpendicular to the web so the web
passes through the sensor gap. The back of the web should
contact the mounting plate. Labels must pass under sensing
area marked [––SENSOR––]. Small labels (38.1mm (1.5in))
must be centered under the sensing area.
Electrical Connections
ATTENTION: Unused wires must be
insulated from contact with other
objects. All power must be off when
installing the sensor. DC ground is
connected to sensor body.
!
Labels must pass under Sensor.
Sensing Area
No power during
connection.
Sensor case is
grounded