beautypg.com

Rockwell Automation GMLC Reference Manual User Manual

Page 343

background image

Publication GMLC-5.2 - November 1999

306

I/O and Event Blocks

When you select Decelerating in If Axis mode, the program branches to
the top (true) node if one of the following occurs as shown below:

the selected servo axis is decelerating (Decel_status = 1) due to a
Move Axis or Jog Axis block

the selected interpolator is decelerating due to an Interpolate Axes
block (Decel_status_Interp0 or …Interp1 = 1)

Feedback On

See the Setup and Installation Manual for your motion controller for a
general discussion of the feedback loop used in the motion controllers.

Gearing Off

If you select Gearing Off in Wait for Axis mode, the current task pauses
until electronic gearing on the selected servo axis is off
(Gearing_status = 0).

When you select Feedback
On in:

The:

Wait for Axis mode

Current task pauses until feedback for the selected servo
axis is on (Feedback_status = 1).

If Axis mode

Program branches to the top (true) node if feedback on the
selected servo axis is on (Feedback_status = 1).

.

Velocity

Time

Axis

Decelerating

(1)

Axis Not

Decelerating (0)