Rockwell Automation GMLC Reference Manual User Manual

Page 71

background image

Publication GMLC-5.2 - November 1999

34

Configuring Control Options

3. In the Applications Options area, select the type of interfaces to be

used:

AxisLink

Selects AxisLink to enable communications for
up to eight motion controllers on a network. An
AxisLink tab appears.
For more information, see the Configuring the
AxisLink Interface
section later in this manual.

DH-485

Select this to enable DH-485 operations for
your controller. A DH-485 tab appears.
Note:

This option is not available for IMC S
Class Basic/Integrated.

For more information, see the Configuring the
DH-485 Interface
section later in this chapter.

Multidrop

Selects a Multidrop interface for your
controller. No tab appears.
For more information, see the Configuring the
Multidrop Interface section later in this
chapter.

Field

Description

Run Program
On Power-up

The motion controller’s program runs
whenever power is applied.

Note: Deselect this option when developing

and debugging your diagram.

!

ATTENTION: Do not use if RIO interface is
selected and the PLC is running the program.

Field

Description