476

Motion Variables

The following figure shows where in the servo loop the motion variables
are monitored. In this figure, the gray boxes represent the motion
variables and the white boxes represent the servo loop components. Each
motion variable is explained following the diagram.

Command_Velocity

Axis Pos. Units/Sec.

Servo_Output_Level

Volts

Servo_Output_Level_mA

mA

Analog_Offset_setpoint

Volts

Analog_Offset_error

Volts

PCAM_auto_correction_to_go

Axis Position Units

PCAM_registration_error

Axis Position Units

PCAM_average_registration_error

Axis Position Units

PCAM_good_registration_count

Integer

PCAM_missing_registration_count

Integer

PCAM_bad_registration_count

Integer

Axis_iq_reference_1394

%Rated

Axis_it_limit_1394

%Rated

Axis_velocity_cmd_1394

RPM

Axis_torque_cmd_1394

%Rated

Variable

Units

Se

rv

o

M

a

st

e

r On

ly

V

irtu

a

l

Imag

in

ar

y