6
Figure 5 Check the status of Collaboration Group 1
•
Click the icon corresponding to Collaboration Group 1 and check the status of its member ports.
The status of GigabitEthernet 0/0 is Down, and that of GigabitEthernet 0/1 is Linkgroup-down, as
shown in
.
Figure 6 Check the status of Collaboration Group 1’s member ports
Configuration Guidelines
Note that when a device is connected to another device through multiple ports, it is recommended that
you do not assign these ports to the same collaboration group. Otherwise, when one port goes down, its
peer port on the remote device may be set to the Link-group down state, in which case, all the ports will
fail to be brought up.