TC Protection

Whether to enable the TC guard function, that is, protection against
topology change (TC) BPDUs.
When receiving TC BPDUs (the BPDUs used to notify topology

changes), the device flushes its forwarding address entries. If someone
forges TC-BPDUs to attack the device, the device will receive a larger

number of TC-BPDUs within a short time and be busy with forwarding

address entry flushing. This affects network stability. With TC guard

enabled, you can prevent frequent flushing of forwarding address
entries.

IMPORTANT:

H3C recommends that you keep this function enabled.

TC Protection Threshold

Set the maximum number of forwarding address entry flushes that the
device can perform within a specific time period after it receives the first

TC-BPDU.


Return to

MSTP configuration task list

.

Configuring MSTP on a Port