beautypg.com

H3C Technologies H3C SecPath F1000-E User Manual

Page 75

background image

3

Figure 3 Network time

Table 1

shows the detailed configuration of network time.

Table 1 Network time configuration items

Item Description

Clock status

Displays the synchronization status of the system clock.

Local Reference Source

Set the IP address of the local clock source to 127.127.1.u, where u
ranges from 0 to 3, representing the NTP process ID.

If the IP address of the local clock source is specified, the local
clock is used as the reference clock, and thus can provide time for

other devices.

If the IP address of the local clock source is not specified, the local
clock is not used as the reference clock.

Stratum

Set the stratum level of the local clock.
The stratum level of the local clock decides the precision of the local
clock. A higher value indicates a lower precision. A stratum 1 clock

has the highest precision, and a stratum 16 clock is not synchronized

and cannot be used as a reference clock.

Source Interface

Set the source interface for an NTP message.
If you do not want the IP address of a certain interface on the local
device to become the destination address of response messages,

you can specify the source interface for NTP messages, so that the

source IP address in the NTP messages is the primary IP address of
this interface. If the specified source interface is down, the source IP

address of the NTP messages sent is the primary IP address of the

outbound interface.

This manual is related to the following products: