These bits define the received power threshold of the Energy above threshold
algorithm. The threshold is calculated by RSSI_BASE_VAL + 2CCA_ED_THRES
[dBm]. Any received power above this level is interpreted as a busy channel.

9.12.14 RX_CTRL – Transceiver Receive Control Register

Bit

7

6

5

4

NA ($14A)

Resx7

Resx6

Resx5

Resx4

RX_CTRL

Read/Write

RW

RW

RW

RW

Initial Value

1

0

1

1

Bit

3

2

1

0

NA ($14A)

PDT_THRES3

PDT_THRES2

PDT_THRES1

PDT_THRES0

RX_CTRL

Read/Write

RW

RW

RW

RW

Initial Value

0

1

1

1

The register controls the sensitivity of the Antenna Diversity Mode. Note that in High
Data Rate modes the ACR module will always be disabled.

Bit 7:4 – Resx7:4 - Reserved

Bit 3:0 – PDT_THRES3:0 - Receiver Sensitivity Control

These register bits control the sensitivity of the receiver correlation unit. If the Antenna
Diversity algorithm is enabled the value shall be set to PDT_THRES = 3. Otherwise it
shall be set back to the reset value. Values not listed in the following table are reserved.

Table 9-44 PDT_THRES Register Bits

Register Bits

Value

Description

0x7

Reset value, to be used if Antenna Diversity
algorithm is disabled

PDT_THRES3:0

0x3

Recommended correlator threshold for
Antenna Diversity operation

9.12.15 SFD_VALUE – Start of Frame Delimiter Value Register

Bit

7

6

5

4

3

2

1

0

NA ($14B)

SFD_VALUE7:0

SFD_VALUE

Read/Write

RW

RW

RW

RW

RW

RW

RW

RW

Initial Value

1

0

1

0

0

1

1

1

This register contains the one octet start-of-frame delimiter (SFD) to synchronize to a
received frame. The lower 4 bits must not be all zero to avoid decoding conflicts.

Bit 7:0 – SFD_VALUE7:0 - Start of Frame Delimiter Value

For compliant IEEE 802.15.4 networks set SFD_VALUE = 0xA7. This is the default
value of the register. To establish non IEEE 802.15.4 compliant networks the SFD value
can be changed to any other value. If enabled a RX_START interrupt is issued only if
the received SFD matches the register content of SFD_VALUE and a valid PHR is
received.