Allied Telesis AT-S60 User Manual
Page 729
AT-S60 Management Software User’s Guide
Section VI: Web Browser Management
729
5. In the Target Address Name field, enter the name of the SNMP
manager, or host, that manages the SNMP activity on your switch.
You can enter a name of up to 32 alphanumeric characters.
6. In the IP Address field, enter the IP address of the host.
Use the following format for an IP address:
XXX.XXX.XXX.XXX
7. In the UDP Port Number field, enter a UDP port number.
You can enter a UDP port in the range of 0 to 65,535. The default
UDP port is 162.
8. In the Timeout field, enter a timeout value in milliseconds.
When an Inform message is generated, it requires a response from
the switch. The timeout value determines how long the switch
considers the Inform message an active message. This parameter
applies to Inform messages only. The range is from 0 to
2,147,483,647 milliseconds. The default value is 1500
milliseconds.
9. In the Retries field, enter the number of times the switch retries, or
resends, an Inform message.
When an Inform message is generated, it requires a response from
the switch. This parameter determines how many times the
switch resends an Inform message. The Retries parameter applies
to Inform messages only. The range is 0 to 255 retries. The default
is 3 retries.
10. In the Tag List field, enter a list of tags that you configured in a
SNMPv3 Notify Table with the Notify Tag parameter.
See Creating a Notify Table Entry on page 722. Enter a Tag List of
up to 256 alphanumeric characters. Use a space to separate
entries, for example:
hwengtag swengtag testengtag
11. In the Target Parameters field, enter a Target Parameters name.
This name can consist of up to 32 alphanumeric characters. The
value configured here must match the value configured with the
Target Parameters Name parameter in the SNMPv3 Target
Parameters Table.
12. In the Storage Type field, enter one of the following storage types for
this table entry:
Volatile
Select this storage type if you do not want the ability to save an
entry in the Target Address Table to the configuration file. After
making changes to a Target Address Table entry with a Volatile
storage type, Save Changes does not appear on the General Tab.