Deleting an snmpv3 target address table entry – Allied Telesis AT-S60 User Manual

Page 358

background image

Chapter 17: SNMPv3 Configuration

Section III: SNMPv3 Protocol

358

This name can consist of up to 32-alphanumeric characters. The
value configured here must match the value configured with the
Target Parameters Name parameter in the Configure SNMPv3
Target Parameters Table.

The following prompt is displayed:

Enter Storage Type [V-Volatile, N-NonVolatile]:

11. Select one of the following storage types for this table entry:

V - Volatile
Select this storage type if you do not want the ability to save an
entry in the SNMPv3 Target Address Table to the configuration
file. After making changes to an SNMPv3 Target Address Table
entry with a Volatile storage type, the S - Save Configuration
Changes option does not appear on the Main Menu.

N-NonVolatile
Select this storage type if you want the ability to save an entry in
the SNMPv3 Target Address Table to the configuration file. After
making changes to an SNMPv3 Target Address entry with a
NonVolatile storage type, the S - Save Configuration Changes
option appears on the Main Menu, allowing you to save your
changes.

Note

The Row Status parameter is a read-only field in the Telnet and Local
interfaces. The Active value indicates the SNMPv3 Target Address
Table entry will take effect immediately.

12. After making changes, type R until you return to the Main Menu. Then

type S to select Save Configuration Changes.

Deleting an

SNMPv3 Target

Address Table

Entry

You may want to delete an entry from the SNMPv3 Target Address Table.
After you delete an SNMPv3 Target Address Table entry, there is no way
to undelete, or recover, it.

To delete an entry in the SNMPv3 Target Address Table, perform the
following procedure:

1. Follow steps 1 through 5 in the procedure described in Creating an

SNMPv3 User Table Entry on page 305. Or, from the Main Menu type
5->1->1->8->5.

The Configure SNMPv3 Table Menu is shown in Figure 101 on
page 306.

2. From the Configure SNMPv3 Table Menu, type 7 to select Configure

SNMPv3 Target Address Table.