AT-S60 Management Software User’s Guide

Section III: SNMPv3 Protocol

349

The Configure SNMPv3 Notify Table Menu is shown in Figure 110.

Figure 110 Configure SNMPv3 Notify Table Menu

3. To create an entry in the table, type 1 to select Create SNMPv3 Table

Entry.

The following prompt is displayed:

Enter Notify Name:

4. Enter the name associated with this trap message.

Enter a name of up to 32-alphanumeric characters. For example,
you might want to define a trap message for hardware
engineering and enter a value of “hardwareengineeringtrap” for
the Notify Name.

The following prompt is displayed:

Enter Notify Tag:

5. Enter the name of the Notify Tag.

Enter a name of up to 32 alphanumeric characters. The following
prompt is displayed:

Enter Notify Type [T-Trap, I-Inform]:

6. Enter one of the following message types:

T-Trap
Indicates this notify table is used to send traps. With this message
type, the switch does not expects a response from the
authoritative entity.

Allied Telesyn AT-8400 Series - ATS60 V2.1.0

Marketing Switch 17

User: Manager

00:14:33 15-Jan-2004

Configure SNMPv3 Notify Table

Notify Name ...................... hardwareengineeringTrap
Notify Tag ....................... hardwareengineeringtag
Notify Type ...................... Trap
Storage Type ..................... NonVolatile
Row Status ....................... Active

1 - Create SNMPv3 Table Entry
2 - Delete SNMPv3 Table Entry
3 - Modify SNMPv3 Table Entry

U - Update Display
R - Return to Previous Menu

Enter your selection?