Chapter 12: Event Log

Section II: Advanced Features

208

5. Choose one or more of the following selections:

The default is to display informational events, error messages, and
warning messages. You can select more than one severity at a
time by separating severities with a comma—for example, E,W.

6. To display the events of a selected AT-S60 software module, type 7 to

select Event Module.

The following prompt is displayed:

Enter Modules to display (ALL, SYSTEM, CLI, EVTLOG, MAC,
STP, VLAN, GARP, PCFG, PMIRR, PTRUNK, PSEC, PACCESS, IP,
ESTACK, FILE, IGMP,TIME,TFTP, HTTP, TELNET, SNMP, RADIUS,
TACACS, ENCO, PKI, SSL, SSH) ->

7. Select one or more software modules to display.

Enter a list of modules separated by a comma—for example,
“system, stp, ptrunk.” For a list of the modules and their
abbreviations, refer to Software Modules on page 210. The default
is ALL, which displays the events for all modules.

8. Once you have set the log filters, type V to select View Log.

Table 6 Event Log Severity Levels

Value

Severity Level

Description

ALL

All levels

Displays all of the following message
types.

E

Error

Switch operation is severely impaired.

W

Warning

An issue may require manager attention.

I

Information

Useful information that can be ignored
during normal operation.

D

Debug

Detailed high-volume information that is
intended for Technical Support.