Allied Telesis AT-S60 User Manual
Page 725

AT-S60 Management Software User’s Guide
Section VI: Web Browser Management
725
3. In the SNMPv3 section of the page, click the circle next to Configure
Notify Table. Then click Configure at the bottom of the page.
The SNMPv3 Notify Table Page is shown in Figure 255 on page
722.
4. Click the circle next to the table entry that you want to change. Then
click Modify.
The Modify SNMPv3 Notify Page is shown in Figure 257
Figure 257 Modify SNMPv3 Notify Page
5. In the Notify Tag field, enter a description name of the Notify Tag.
Enter a name of up to 32 alphanumeric characters.
6. In the Notify Type field, enter one of the following message types:
Trap
Indicates this notify table is used to send traps. With this message
type, the switch does not expects a response from the host.
Inform
Indicates this notify table is used to send inform messages. With
this message type, the switch expects a response from the host.
7. In the Storage Type field, select one of the following storage types for
this table entry:
Volatile
Select this storage type if you do not want the ability to save an
entry in the Notify Table to the configuration file. After making
changes to an Notify Table entry with a Volatile storage type, Save
Changes does not appear on the Configuration Tab.