Allied Telesis AT-S60 User Manual
Page 209
AT-S60 Management Software User’s Guide
Section II: Advanced Features
209
An example of an event log is show in Figure 65. This log is in the
Full display mode. The Normal display mode does not include the
Filename, Line Number, and Event ID items.
Figure 65 Event Log Example
The columns in the log are described below:
❑ S (Severity) - The event’s severity. Table 7 defines the different
severity levels:
Allied Telesyn Ethernet Switch AT-S60 V2.1.0
Production Switch 32
User: Manager
11:20:02 02-Jan-2004
Event Log
S
Date
Time
EventID
Source File:Line Number
Event
------------------------------------------------------------------
I
2/01/04
09:11:02
073001
garpmain.c:259
garp: GARP initialized
I
2/01/04
09:55:15
083001
portconfig.c:961
pcfg: PortConfig initialized
I
2/01/04
12:24:12
093001
mirrorapp.c:158
pmirr: Mirror initialization succeeded
I
2/01/04
12:47:08
043016
macapp.c:1431
mac: Delete Dynamic MAC by Port[2.7]
succeeded
Temporary (Memory) Log Events 1 - 4 of 212
P - Previous Page N - Next PageF - First Page L - Last Page
R - Return to Previous Menu
Enter your selection?
Table 7 Event Log Severity Levels
Value
Severity Level
Description
E
Error
Switch operation is severely impaired.
W
Warning
An issue may require manager attention.
I
Information
Useful information that can be ignored
during normal operation.
D
Debug
Detailed high-volume information that is
intended for Technical Support.