Allied Telesis AT-S60 User Manual
Page 62

Chapter 3: Basic Switch Parameters
Section I: Basic Features
62
11. Enter an IP address of your SNTP or NTP server.
Use the standard IP format: xxx.xxx.xxx.xxx
12. Type 4 - UTC Offset to specify a difference between the UTC and local
time.
Note
If you have enabled DHCP, the switch automatically attempts to
determine this value. In this case, you do not need to configure a
value for the UTC Offset parameter.
The following prompt is displayed:
Enter UTC Offset [-12 to 12] -> 0
13. Enter a UTC Offset time.
The default is 0 hours. The range is -12 to +12 hours.
14. Type 5 - Daylight Savings Time (DST) to enable or disable the switch’s
ability to adjust its system time to daylight savings time.
The following prompt is displayed:
Adjust for Daylight Savings Time (E - Enabled, D -
Disabled) ->
15. Select one of the following:
❑ Type E (for Enabled) to allow the switch to adjust system time to
daylight savings time. This is the default value.
❑ Type D (for Disabled) to not allow the switch to adjust system time
to daylight savings time.
16. Type 6 - Poll Interval to specify the time interval between two
successive queries to the SNTP server.
The following prompt is displayed:
Enter interval to poll SNTP server [60 to 1200] ->
600
17. Enter the number of seconds the switch waits to poll the SNTP server.
The default is 600 seconds. The range is from 60 to 1200 seconds.
Note
The Last Delta field displays the last adjustment that was applied to
system time due to a drift in the system clock between two
successive queries to the SNTP server. This is a read only field.
18. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.