Configuring history sampling, Conf – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual
Page 771

Brocade 6910 Ethernet Access Switch Configuration Guide
715
53-1002651-02
34
Port Configuration
Configuring History Sampling
Use the Interface > Port > History or Interface > Trunk > History page to configure a periodic
sampling of statistics, specifying the sampling interval and number of samples.
CLI References
•
•
Command Usage
For a description of the statistics displayed on these pages, see
“Showing Port or Trunk Statistics”
Parameters
These parameters are displayed:
Add
•
Port – Port number. (Range: 1-12)
•
HIstory Name – Name of sample interval. (Range: 1-32 characters)
•
Interval - The interval for sampling statistics. (Range: 1-1440 minutes)
•
Requested Buckets - The number of samples to take. (Range: 1-96)
Show
•
Port – Port number. (Range: 1-12)
•
HIstory Name – Name of sample interval. (Default settings: 15min, 1day)
•
Interval - The interval for sampling statistics.
•
Requested Buckets - The number of samples to take.
Show Details
•
Mode
•
Status – Shows the sample parameters.
•
Current Entry – Shows current statistics for the specified port and named sample.
•
Input Previous Entries – Shows statistical history for ingress traffic.
•
Output Previous Entries – Shows statistical history for egress traffic.
•
Port – Port number. (Range: 1-12)
•
Name – Name of sample interval.
Interface
To configure a periodic sample of statistics:
1. Click Interface, Port, Statistics, or Interface, Trunk, Statistics.
2. Select Add from the Action menu.
3. Select an interface from the Port or Trunk list.
4. Enter the sample name, the interval, and the number of buckets requested.
5. Click Apply.