Show ethernet cfm errors, Table 128 – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual
Page 597

Brocade 6910 Ethernet Access Switch Configuration Guide
541
53-1002651-02
25
CFM Commands
Command Mode
Privileged Exec
Command Usage
Use this command without any keywords to clear all entries in the error database. Use the domain
keyword to clear the error database for a specific domain, or the level keyword to clear it for a
specific maintenance level.
Example
Console#clear ethernet cfm errors domain voip
Console#
show ethernet cfm errors
This command displays the CFM continuity check errors logged on this device.
Syntax
show ethernet cfm errors [domain domain-name | level level-id]
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
level-id – Authorized maintenance level for this domain. (Range: 0-7)
Default Setting
None
Command Mode
Privileged Exec
Example
Console#show ethernet cfm errors
Level VLAN MPID Interface Remote MAC Reason MA Name
----- ---- ---- --------- ----------------- ---------------- ----------------
5 2 40 Eth 1/1 ab.2f.9c.00.05.01 LEAK provider_1_2
Console#
TABLE 128
show ethernet cfm errors - display description
Field
Description
Level
Maintenance level associated with this entry.
VLAN
VLAN in which this error occurred.
MPID
Identifier of remote MEP.
Interface
Port at which the error was recorded
Remote MAC
MAC address of remote MEP.