This parameter is used to ensure that received R-APS PDUs are directed for this ring. A unique
level should be configured for each local ring if there are many R-APS PDUs passing through
this switch.
•
If CFM continuity check messages are used to monitor the link status of an ERPS ring node as
specified by the
command, then the MEG level set by the meg-level command
must match the authorized maintenance level of the CFM domain to which the specified MEP
belongs.
Example
Console(config-erps)#meg-level 0
Console(config-erps)#
Related Commands
mep-monitor
This command specifies the CFM MEPs used to monitor the link on a ring node. Use the no form to
restore the default setting.
Syntax
mep-monitor {east | west} mep mpid
east - Connects to next ring node to the east.
west - Connects to next ring node to the west.
mpid – Maintenance end point identifier. (Range: 1-8191)
Default Setting
None
Command Mode
ERPS Configuration
Command Usage
•
If this command is used to monitor the link status of an ERPS node with CFM continuity check
messages, then the MEG level set by the
command must match the authorized
maintenance level of the CFM domain to which the specified MEP belongs.
•
To ensure complete monitoring of a ring node, use the mep-monitor command to specify the
CFM MEPs used to monitor both the east and west ports of the ring node.