Show ethernet cfm maintenance-points remote detail – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual
Page 591
Brocade 6910 Ethernet Access Switch Configuration Guide
535
53-1002651-02
25
CFM Commands
show ethernet cfm maintenance-points remote detail
This command displays detailed CFM information about a remote MEP in the continuity check
database.
Syntax
show ethernet cfm maintenance-points remote detail
{mac mac-address | mpid mpid}
[domain domain-name | level level-id | ma ma-name]
mac-address – MAC address of a remote maintenance point.
This address can be entered in either of the following formats: xx-xx-xx-xx-xx-xx or
xxxxxxxxxxxx
mpid – Maintenance end point identifier. (Range: 1-8191)
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
level-id – Authorized maintenance level for this domain. (Range: 0-7)
ma-name – Maintenance association name. (Range: 1-43 alphanumeric characters,
maximum length is 44 minus the length of the domain name)
Default Setting
None
Received RDI
Receive status of remote defect indication (RDI) messages on the MEP.
AIS Status
Shows if MEPs within the specified MA are enabled to send frames with AIS
information following detection of defect conditions.
AIS Period
The interval at which AIS information is sent.
AIS Transmit Level
The maintenance level at which AIS information will be sent for the specified MEP.
Suppress Alarm
Shows if the specified MEP is configured to suppress sending frames containing AIS
information following the detection of defect conditions.
Suppressing Alarms
Shows if the specified MEP is currently suppressing sending frames containing AIS
information following the detection of defect conditions.
Delay Measure
Configuration settings for periodic delay-measure messages.
Status
Shows if transmission of delay-measure messages is enabled or not.
Method
Shows if one-way, two-way or no delay-measure messages are configured.
Destination
The destination MEP for transmitted delay-measure messages.
Loss Measure
Configuration settings for periodic loss-measure messages.
Dual-ended Status
Shows if dual-ended loss-measure messages are enabled or not.
Dual-ended
Destination
Destination MEP for dual-ended loss-measure messages.
Single-ended Status
Shows if single-ended loss-measure messages are enabled or not.
Single-ended
Destination
Destination MEP for single-ended loss-measure messages.
TABLE 126
show ethernet cfm maintenance-points local detail mep - display (Continued)
Field
Description