568

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002651-02

25

CFM Commands

show ethernet cfm loss-measure single-ended

This command displays near-end and far-end frame loss for the on-demand single-ended
loss-measure test.

Syntax

show ethernet cfm loss-measure single-ended

Command Mode
Privileged Exec

Example

Console#show ethernet cfm loss-measure single-ended

Received Time Far-end Frame Loss Near-end Frame Loss

-------------------- ------------------ -------------------

Jun 18 08:35:15 2012 0 0

Jun 18 08:35:16 2012 0 0

Jun 18 08:35:17 2012 0 0

Jun 18 08:35:18 2012 0 0

Jun 18 08:35:19 2012 0 0