OAM Commands
•
Dying gasp events are caused by an unrecoverable failure, such as a power failure or device
reset.
NOTE
When system power fails, the switch will always send a dying gasp trap message prior to power
down.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam critical-link-event dying-gasp
Console(config-if)#
efm oam link-monitor frame
This command enables reporting of errored frame link events. Use the no form to disable this
function.
Syntax
[no] efm oam link-monitor frame
Default Setting
Enabled
Command Mode
Interface Configuration
Command Usage
•
An errored frame is a frame in which one or more bits are errored.
•
If this feature is enabled and an errored frame link event occurs, the local OAM entity (this
switch) sends an Event Notification OAMPDU.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame
Console(config-if)#
efm oam link-monitor frame threshold
This command sets the threshold for errored frame link events. Use the no form to restore the
default setting.
Syntax
[no] efm oam link-monitor frame threshold count
count - The threshold for errored frame link events. (Range: 1-65535)
Default Setting
1