beautypg.com

Efm oam link-monitor frame, Efm oam link-monitor frame threshold – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual

Page 627

background image

Brocade 6910 Ethernet Access Switch Configuration Guide

571

53-1002651-02

26

OAM Commands

Dying gasp events are caused by an unrecoverable failure, such as a power failure or device
reset.

NOTE

When system power fails, the switch will always send a dying gasp trap message prior to power
down.

Example

Console(config)#interface ethernet 1/1

Console(config-if)#efm oam critical-link-event dying-gasp

Console(config-if)#

efm oam link-monitor frame

This command enables reporting of errored frame link events. Use the no form to disable this
function.

Syntax

[no] efm oam link-monitor frame

Default Setting
Enabled

Command Mode
Interface Configuration

Command Usage

An errored frame is a frame in which one or more bits are errored.

If this feature is enabled and an errored frame link event occurs, the local OAM entity (this
switch) sends an Event Notification OAMPDU.

Example

Console(config)#interface ethernet 1/1

Console(config-if)#efm oam link-monitor frame

Console(config-if)#

efm oam link-monitor frame threshold

This command sets the threshold for errored frame link events. Use the no form to restore the
default setting.

Syntax

[no] efm oam link-monitor frame threshold count

count - The threshold for errored frame link events. (Range: 1-65535)

Default Setting
1