CFM Commands
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
port-channel channel-id (Range: 1-12)
level-id – Maintenance level for this domain. (Range: 0-7)
Default Setting
None
Command Mode
Privileged Exec
Command Usage
•
Use the mep keyword with this command to display the MEPs configured on this device as
DSAPs through the
command.
•
Using the mip keyword with this command to display the MIPs generated on this device by the
CFM protocol when the mip-creation method is set to either “default” or “explicit” by the
command.
Example
This example shows all MEPs configured on this device for maintenance domain rd.
Console#show ethernet cfm maintenance-points local mep
MPID MD Name Level Direct VLAN Port CC Status MAC Address
---- ---------------- ----- ------ ---- -------- --------- -----------------
1 rd 0 UP 1 Eth 1/ 1 Enabled 00-12-CF-3A-A8-C0
Console#
show ethernet cfm maintenance-points local detail mep
This command displays detailed CFM information about a local MEP in the continuity check
database.
Syntax
show ethernet cfm maintenance-points local detail mep [domain domain-name |
interface interface | level level-id]
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
interface – Displays CFM status for the specified interface.
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
port-channel channel-id (Range: 1-12)
level-id – Maintenance level for this domain. (Range: 0-7)
Default Setting
None