beautypg.com

Mep fault-notify reset-time, Show ethernet cfm fault-notify-generator, Fault-notify reset-time – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual

Page 609

background image

Brocade 6910 Ethernet Access Switch Configuration Guide

553

53-1002651-02

25

CFM Commands

mep fault-notify reset-time

This command configures the time after a fault alarm has been issued, and no defect exists, before
another fault alarm can be issued. Use the no form to restore the default setting.

Syntax

mep fault-notify reset-time reset-time

no fault-notify reset-time

reset-time – The time that must pass without any further defects indicated before another
fault alarm can be generated. (Range: 3-10 seconds)

Default Setting
10 seconds

Command Mode
CFM Domain Configuration

Example
This example sets the reset time after which another fault alarm can be generated.

Console(config)#ethernet cfm domain index 1 name voip level 3

Console(config-ether-cfm)#mep fault-notify reset-time 7

Console(config-ether-cfm)#

show ethernet cfm fault-notify-generator

This command displays configuration settings for the fault notification generator.

Syntax

show ethernet cfm fault-notify-generator mep mpid

mpid – Maintenance end point identifier. (Range: 1-8191)

Default Setting
None

Command Mode
Privileged Exec

Example
This example shows the fault notification settings configured for one MEP.

Console#show ethernet cfm fault-notify-generator mep 1

MD Name MA Name Highest Defect Lowest Alarm Alarm Time Reset Time

------------ ------------ -------------- ------------- ---------- ----------

voip rd none macRemErrXcon 3sec. 10sec.

Console#