Mep fault-notify reset-time, Show ethernet cfm fault-notify-generator, Fault-notify reset-time – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual
Page 609

Brocade 6910 Ethernet Access Switch Configuration Guide
553
53-1002651-02
25
CFM Commands
mep fault-notify reset-time
This command configures the time after a fault alarm has been issued, and no defect exists, before
another fault alarm can be issued. Use the no form to restore the default setting.
Syntax
mep fault-notify reset-time reset-time
no fault-notify reset-time
reset-time – The time that must pass without any further defects indicated before another
fault alarm can be generated. (Range: 3-10 seconds)
Default Setting
10 seconds
Command Mode
CFM Domain Configuration
Example
This example sets the reset time after which another fault alarm can be generated.
Console(config)#ethernet cfm domain index 1 name voip level 3
Console(config-ether-cfm)#mep fault-notify reset-time 7
Console(config-ether-cfm)#
show ethernet cfm fault-notify-generator
This command displays configuration settings for the fault notification generator.
Syntax
show ethernet cfm fault-notify-generator mep mpid
mpid – Maintenance end point identifier. (Range: 1-8191)
Default Setting
None
Command Mode
Privileged Exec
Example
This example shows the fault notification settings configured for one MEP.
Console#show ethernet cfm fault-notify-generator mep 1
MD Name MA Name Highest Defect Lowest Alarm Alarm Time Reset Time
------------ ------------ -------------- ------------- ---------- ----------
voip rd none macRemErrXcon 3sec. 10sec.
Console#