beautypg.com

Silent-time – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual

Page 136

background image

80

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002651-02

5

Line

Default Setting
The default value is three attempts.

Command Mode
Line Configuration

Command Usage
When the logon attempt threshold is reached, the system interface becomes silent for a specified
amount of time before allowing the next logon attempt. (Use the

silent-time

command to set this

interval.) When this threshold is reached for Telnet, the Telnet logon interface shuts down.

Example
To set the password threshold to five attempts, enter this command:

Console(config-line)#password-thresh 5

Console(config-line)#

Related Commands

“silent-time”

on page 80

silent-time

This command sets the amount of time the management console is inaccessible after the number
of unsuccessful logon attempts exceeds the threshold set by the

password-thresh

command. Use

the no form to remove the silent time value.

Syntax

silent-time [seconds]

no silent-time

seconds - The number of seconds to disable console response. (Range: 0-65535, where 0
means disabled)

Default Setting
The default value is no silent-time.

Command Mode
Line Configuration

Example
To set the silent time to 60 seconds, enter this command:

Console(config-line)#silent-time 60

Console(config-line)#

Related Commands

“password-thresh”