CFM Commands

The cross-check process is disabled by default, and must be manually started using this
command with the enable keyword.

Example
This example enables cross-checking within the specified maintenance association.

Console#ethernet cfm mep crosscheck enable md voip ma rd

Console#

show ethernet cfm maintenance-points remote crosscheck

This command displays information about remote MEPs statically configured in a cross-check list.

Syntax

show ethernet cfm maintenance-points remote crosscheck

[domain domain-name | mpid mpid]

domain-name – Domain name. (Range: 1-43 alphanumeric characters)

mpid – Maintenance end point identifier. (Range: 1-8191)

Default Setting
None

Command Mode
Privileged Exec

Example
This example shows all remote MEPs statically configured on this device.

Console#show ethernet cfm maintenance-points remote crosscheck

MPID MA Name Level VLAN MEP Up Remote MAC

---- -------------------- ----- ---- ------ ------------------

2 downtown 4 2 Yes 00-0D-54-FC-A2-73

Console#

Link Trace Operations

ethernet cfm linktrace cache

This command enables caching of CFM data learned through link trace messages. Use the no form
to disable caching.

Syntax

[no] ethernet cfm linktrace cache

Default Setting
Enabled

Command Mode
Global Configuration