Show mvr6, Table 118 – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual
Page 549
Brocade 6910 Ethernet Access Switch Configuration Guide
493
53-1002651-02
23
MVR for IPv6
Example
The following statically assigns a multicast group to a receiver port:
Console(config)#interface ethernet 1/2
Console(config-if)#mvr6 domain 1 type receiver
Console(config-if)#mvr6 domain 1 vlan 2 group ff00::1
Console(config-if)#
show mvr6
This command shows information about MVR domain settings, including MVR operational status,
the multicast VLAN, the current number of group addresses, and the upstream source IP address.
Syntax
show mvr6 [domain domain-id]
domain-id - An independent multicast domain. (Range: 1-5)
Default Setting
Displays configuration settings for all MVR domains.
Command Mode
Privileged Exec
Example
The following shows the MVR settings:
Console#show mvr6
MVR6 Proxy Switching : Enabled
MVR6 Robustness Value : 1
MVR6 Domain : 1
MVR6 Config Status : Enabled
MVR6 Running Status : Active
MVR6 Multicast VLAN : 1
MVR6 Upstream Source IP : FF05::25
Console#
TABLE 118
show mvr6 - display description
Field
Description
MVR Proxy Switching
Shows if MVR proxy switching is enabled
MVR Robustness Value
Shows the number of reports or query messages sent when proxy switching is
enabled
MVR6 Domain
An independent multicast domain.
MVR6 Config Status
Shows if MVR is globally enabled on the switch.
MVR6 Running Status
Indicates whether or not all necessary conditions in the MVR environment are
satisfied. (Running status is true as long as MVR Status is enabled, and the
specified MVR VLAN exists, and a source port with a valid link has been configured
(using the
command.)
MVR6 Multicast VLAN
Shows the VLAN used to transport all MVR multicast traffic.
MVR6 Upstream Source IP
The source IP address assigned to all upstream control packets.