Brocade 6910 Ethernet Access Switch Configuration Guide
365
53-1002651-02
19
ERPS Commands
Example
Console(config-erps)#ring-port east interface ethernet 1/12
Console(config-erps)#
rpl owner
This command configures a ring node to be the Ring Protection Link (RPL) owner or a non-owner.
Syntax
[no] rpl owner
Default Setting
non-owner
Command Mode
ERPS Configuration
Command Usage
•
Only one RPL owner can be configured on a ring. The owner blocks traffic on the RPL during
Idle state, and unblocks it during Protection state (that is, when a signal fault is detected on
the ring).
•
The east and west connections to the ring must be specified for all ring nodes using the
command. When this switch is configured as the RPL owner, the west ring port is
automatically set as being connected to the RPL.
Example
Console(config-erps)#rpl owner
Console(config-erps)#
wtr-timer
This command sets the wait-to-restore timer which is used to verify that the ring has stabilized
before blocking the RPL after recovery from a signal failure. Use the no form to restore the default
setting.
Syntax
wtr-timer minutes
minutes - The wait-to-restore timer is used to verify that the ring has stabilized before
blocking the RPL after recovery from a signal failure. (Range: 5-12 minutes)
Default Setting
5 minutes
Command Mode
ERPS Configuration
Command Usage
If the switch goes into ring protection state due to a signal failure, after the failure condition is
cleared, the RPL owner will start the wait-to-restore timer and wait until it expires to verify that the
ring has stabilized before blocking the RPL and returning to the Idle (normal operating) state.