beautypg.com

Displaying local meps, Figure 316 t – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual

Page 1082

background image

1026

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002651-02

43

Connectivity Fault Management

FIGURE 316

Transmitting Single-Ended Loss-Measure Messages

Displaying Local MEPs

Use the Administration > CFM > Show Information (Show Local MEP) page to show information for
the MEPs configured on this device.

CLI References

“show ethernet cfm maintenance-points local”

on page 532

“show ethernet cfm maintenance-points local detail mep”

on page 533

Parameters
These parameters are displayed:

MEP ID – Maintenance end point identifier.

MD Name – Maintenance domain name.

Level – Authorized maintenance level for this domain.

Direction – Direction in which the MEP communicates CFM messages:

Down indicates that the MEP is facing away from the switch, and transmits CFM messages
towards, and receives them from, the direction of the physical medium.

Up indicates that the MEP faces inward toward the switch cross-connect matrix, and
transmits CFM messages towards, and receives them from, the direction of the internal
bridge relay mechanism.

Primary VLAN – Service VLAN ID.

Interface – Physical interface of this entry (either a port or trunk).

CC Status – Shows administrative status of CCMs.

MAC Address – MAC address of this MEP entry.