Displaying local meps, Figure 316 t – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual
Page 1082

1026
Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002651-02
43
Connectivity Fault Management
FIGURE 316
Transmitting Single-Ended Loss-Measure Messages
Displaying Local MEPs
Use the Administration > CFM > Show Information (Show Local MEP) page to show information for
the MEPs configured on this device.
CLI References
•
“show ethernet cfm maintenance-points local”
•
“show ethernet cfm maintenance-points local detail mep”
Parameters
These parameters are displayed:
•
MEP ID – Maintenance end point identifier.
•
MD Name – Maintenance domain name.
•
Level – Authorized maintenance level for this domain.
•
Direction – Direction in which the MEP communicates CFM messages:
•
Down indicates that the MEP is facing away from the switch, and transmits CFM messages
towards, and receives them from, the direction of the physical medium.
•
Up indicates that the MEP faces inward toward the switch cross-connect matrix, and
transmits CFM messages towards, and receives them from, the direction of the internal
bridge relay mechanism.
•
Primary VLAN – Service VLAN ID.
•
Interface – Physical interface of this entry (either a port or trunk).
•
CC Status – Shows administrative status of CCMs.
•
MAC Address – MAC address of this MEP entry.