ethernet cfm loss-measure single-ended
This command sends on-demand loss-measure information to a specified MEP, stamped with the
time of transmission.
Syntax
ethernet cfm loss-measure single-ended [src-mep source-mpid] dest-mep destination-mpid
md domain-name ma ma-name [count transmit-count] [interval interval]
source-mpid – The identifier of a source MEP that will send loss-measure messages.
(Range: 1-8191)
destination-mpid – The identifier of a remote MEP that is the target of loss-measure
messages. (Range: 1-8191)
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
ma-name – Maintenance association name. (Range: 1-43 alphanumeric characters,
maximum length is 44 minus the length of the domain name)
count – The number of times to send a loss-measure message. (Range: 1-5)
interval – The interval between the transmission of loss-measure messages.
(Range: 1-5 seconds)
Default Setting
Count: 5
Interval: 1 second
Command Mode
Privileged Exec
Command Usage
•
Both the source and destination MEP must be configured for the same MA before using this
command.
•
For more information on how single-ended loss measurements are calculated, see the periodic
ethernet cfm loss-measure enable
command.
Example
This example sends one-way loss-measure requests to a remote MEP.
Console#ethernet cfm loss-measure single-ended dest-mep 2 md voip ma rd
Type ESC to abort.
Sending 5 Ethernet CFM loss measurement message.
Received Time Far-end Frame Loss Near-end Frame Loss
-------------------- ------------------ -------------------
Jun 18 08:35:15 2012 0 0
Jun 18 08:35:16 2012 0 0
Jun 18 08:35:17 2012 0 0
Jun 18 08:35:18 2012 0 0
Jun 18 08:35:19 2012 0 0
Console#