CFM Commands

Jun 18 05:04:39 2012 10 10

Jun 18 05:04:40 2012 10 0

Jun 18 05:04:41 2012 < 10 10

Delay time min/avg/max=0/12/20 ms.

Console#

Loss Measure Operations

ethernet cfm loss-measure dual-ended destination

This command sets the destination MEP for periodically transmitted continuity check messages
(CCM), including request for dual-ended frame loss measurements. Use the no form to clear a
destination.

Syntax

ethernet cfm loss-measure dual-ended destination dest-mep destination-mpid

md domain-name ma ma-name mpid source-mpid

no ethernet cfm delay-measure destination md domain-name ma ma-name mpid mpid

destination-mpid – The identifier of a remote MEP that is the target of loss-measure
messages. (Range: 1-8191)

domain-name – Domain name. (Range: 1-43 alphanumeric characters)

ma-name – Maintenance association name. (Range: 1-43 alphanumeric characters,
maximum length is 44 minus the length of the domain name)

source-mpid – Maintenance end point identifier of a local MEP that is the source of
loss-measure messages. (Range: 1-8191)

Default Setting
None

Command Mode
Global Configuration

Command Usage
To modify settings for a destination, first disable the transmission of loss-measure messages with
the

no ethernet cfm loss-measure enable

command.

Example
This example sets the periodic loss-measure message destination for a MEP.

Console(config)#ethernet cfm loss-measure dual-ended destination dest-mep 2

md voip ma rd mpid 1

Console(config)#