Interface Commands

Command Mode
Interface Configuration (Ethernet)

Command Usage

A high-threshold alarm or warning message is sent if the current value is greater than or equal
to the threshold, and the last sample value was less than the threshold. After a rising event has
been generated, another such event will not be generated until the sampled value has fallen
below the high threshold and reaches the low threshold.

A low-threshold alarm or warning message is sent if the current value is less than or equal to
the threshold, and the last sample value was greater than the threshold. After a falling event
has been generated, another such event will not be generated until the sampled value has
risen above the low threshold and reaches the high threshold.

Threshold events are triggered as described above to avoid a hysteresis effect which would
continuously trigger event messages if the power level were to fluctuate just above and below
either the high threshold or the low threshold.

Trap messages configured by this command are sent to any management station configured by
the

snmp-server host

command.

This command only applies to transceiver vendor "BROCADE".

Example
The following example sets alarm thresholds for the transceiver current at port 1.

Console(config)interface ethernet 1/1

Console(config-if)#transceiver-threshold current low-alarm 100

Console(config-if)#transceiver-threshold rx-power high-alarm 700

Console#

transceiver-threshold rx-power

This command sends a trap when the power level of the received signal falls outside of the
specified thresholds.

Syntax

transceiver-threshold rx-power {high-alarm | high-warning | low-alarm | low-warning}

threshold-value

high-alarm – Sends an alarm message when the high power threshold is crossed.

high-warning – Sends a warning message when the high power threshold is crossed.

low-alarm – Sends an alarm message when the low power threshold is crossed.

low-warning – Sends a warning message when the low power threshold is crossed.

threshold-value – The power threshold of the received signal. (Range: -9999 - 9999 in
units of 0.01 dBm)

Default Setting
None

Command Mode
Interface Configuration (Ethernet)